Ultrasone foutdetector
-
ultrasone diktemaat
-
De Maat van de deklaagdikte
-
draagbaar hardheidsmeetapparaat
-
x-ray gebrekdetector
-
Röntgenpijpleiders
-
Vakantie detector
-
het magnetische deeltje testen
-
Eddy Current Testing Equipment
-
Penetranttesten
-
Durometer van de kust
-
brinell hardheidsmeetapparaat
-
Rockwell-hardheidsmeetapparaat
-
De micro- Hardheidsmeetapparaat van Vickers
-
Materiële hardheidstester
-
trillingsmeter
-
Test van de oppervlaktrauwheid
-
Profielprojector
-
Glancemeters
-
concrete testhamer
-
Laser-infraroodthermometer
-
BobType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
WillemType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
TomType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
LeeuwType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
Eddy Current Conductivity Meter Digital Eddy Current Testing Equipment Eddy Current Conductivity Tester

Neem contact met me op voor gratis monsters en coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skypen: sales10@aixton.com
Als u zich zorgen maakt, bieden we 24-uurs online hulp.
xMetingstechnologie | Eddy Current | werkfrequentie | 60KHz, 120KHz |
---|---|---|---|
Scherm weergeven | 240X320 pixel TFT LCD | L*B*H | 180*90*40 mm |
Meetbereik | 6.9%IACS-110%IACS ((4.0MS/m-64MS/m) | Het onderscheidingspercentage | 0.01% IACS |
Probe gecompenseerd | 0.3 mm | Het meten van nauwkeurigheid | 0°C tot 45°C ± 0,1%IACS~ 0,5%IACS |
Gegevensopslag | Kan 1000 meetgegevens opslaan | Relatieve luchtvochtigheid | 0~95% |
Werktemperatuur | 0℃~50℃ | Naam van het product | Eddy-stroomgeleidbaarheidstester |
Markeren | eddy current testing machine,magnetic flaw detector |
Digital Eddy Current Testing Equipment , TFT LCD Eddy Current Conductivity Meter
Eddy Current Conductivity Meter Digital Eddy Current Testing Equipment Eddy Current Conductivity Tester
HEC-100 series of eddy current electrical conductivity meters, which are designed for quick & convenient measurement of material property, such as material separate, quality control, material state check and so on. The products use the electromagnetism testing principle, can testing objects focus on non-ferromagnetic materials.
HEC-100 series products use 60 KHz (aviation industry standard) to inspirit, the testing data can be read in two kinds of unit (%IACS and MS/m). The products can test electrical conductivity and resistivity at the same time, and they include the intelligent temperature and lift-off compensations, thus can guarantee the testing accuracy of each measurement. The big typeface and the back light illumination designs are advantageous for users to take the testing data even in low light condition. The products use the high property battery to make sure it keeps more running time, and because of their mini-size, you could easy to carry and to grasp hold. The design of the products are more advantages, such as users can replace the probe in the outdoor, don’t need to return the company to adjust the probe into matching the meter. About HEC-100, two kinds of operate languages (English &Chinese) satisfy different national demand. It can store 1000 measurement data, moreover, users can use USB connect the meter to a PC to create testing report.
Digital Portable Eddy Current Conductivity Meter with TFT - LCD
Application:
★ Absolute measurement of electrical conductivity of nearly all non-ferrous metals;(Ti – Ag)
★ In the aerospace and automotive industry, monitor the process of heat treatment, the strength and hardness of aluminum alloy;
★ Test the conductivity whenthe aluminum have not been oxidized;
★ Measurement the purity of non-ferrous metals;
★ Test the resistivity ofconductivematerials;
★ Analyze thermal properties ofmaterials.
Hand-held eddy current conductivity tester for NF-metals with automatic normalization of the conductivity values to 20°C through temperature sensor.
HEC-101 Technical parameters
Measurement technology | Eddy current | |
Operating frequency | 60KHz,120KHz | |
Display screen | 240X320 pixels TFT-LCD | |
L*B*H | 180*90*40 mm | |
Instrument case | Anti-intense impact, water-proofing polyester; Toolbox. | |
Weight | 300g | |
conductivity standard block | Verify and guarantee temperature compensation. | |
Measuring range | 6.9%IACS-110%IACS(4.0MS/m-64MS/m) | |
Distinguishing rate | 0.01% IACS | |
Probe compensated | 0.3mm | |
Measuring accuracy |
0°C to 45°C ± 0.1%IACS~ 0.5%IACS |
|
Temperature compensation | Automatic compensation to the value of 20 ℃. | |
Normal work environment | Relative humidity | 0~95% |
Operating temperature | 0℃~50℃ | |
Data storage | Can store 1000 measurement data. | |
Probe |
Diameter: 12mm Applicable to minimum measuring area diameter at 60KHz is 12mm. |
|
Diameter: 8mm Applicable to minimum measuring area diameter at 60KHz is 8mm. |
|
Products use and maintain
Ⅰ,In order to prevent electric shock or catch fire, please use the suitable power adapter.
Ⅱ,Avoid to drop and hit the instrument.
Ⅲ,Please keep the instrument clean and dry, please check the probe and standard block weather are damaged or corrupted before using.
Ⅳ,Please do not operate in wet, explosive, chemic or high temperature environment.
Ⅴ,Do not voluntarily replace the spare part, if the product is abnormal or has suspicious breakdown, please contact with technology department or serviceman of our company for help