Ultrasone foutdetector
-
ultrasone diktemaat
-
De Maat van de deklaagdikte
-
draagbaar hardheidsmeetapparaat
-
x-ray gebrekdetector
-
Röntgenpijpleiders
-
Vakantie detector
-
het magnetische deeltje testen
-
Eddy Current Testing Equipment
-
Penetranttesten
-
Durometer van de kust
-
brinell hardheidsmeetapparaat
-
Rockwell-hardheidsmeetapparaat
-
De micro- Hardheidsmeetapparaat van Vickers
-
Materiële hardheidstester
-
trillingsmeter
-
Test van de oppervlaktrauwheid
-
Profielprojector
-
Glancemeters
-
concrete testhamer
-
Laser-infraroodthermometer
-
BobType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
WillemType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
TomType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
LeeuwType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
Directional Radiation Portable X-Ray Flaw Detector XXG1605 With Ceramic X-Ray Tube 160kv

Neem contact met me op voor gratis monsters en coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skypen: sales10@aixton.com
Als u zich zorgen maakt, bieden we 24-uurs online hulp.
xBuismateriaal | van keramiek | Buizenspanning | 60-160KV |
---|---|---|---|
Buis stroom | 5mA/6mA | Invoer KW | 1.5 kW |
Maximum penetratie | 18 mm | ||
Markeren | x ray inspection equipment,welding x ray machine |
Directional radiation portable X-ray flaw detector XXQ-1605 glass tube
(Glass x-ray tube)
XXQ series are suitable for the material directional of thin iron plate, aluminum, rubber and so on, may get very good picture quality and clarity.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification:
| Output voltage | Input | Focus spot | Beam angle | Max penetration | Weight (KG) | Dimensions (mm) | ||
Generator | Controller | Generator | Controller | ||||||
XXQ-1605 | 60-160 | 1.5 | 0.8X0.8 | 40° | 18 | 18 | 9.4 | 225x225x600 | 350x290x160 |
Standard Delivery
Directional glass X-ray tube | 1 Pcs |
|
Generator | 1 Set |
|
High voltage joins cable | 1 Pcs | 25 Meters |
Controller | 1 Set |
|
Power cable | 1 Pcs | 10 Meters |
Grounding cable | 1 Pcs | 5 Meters |
Accessories | 1 Set |
|
(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |