Ultrasone foutdetector
-
ultrasone diktemaat
-
De Maat van de deklaagdikte
-
draagbaar hardheidsmeetapparaat
-
x-ray gebrekdetector
-
Röntgenpijpleiders
-
Vakantie detector
-
het magnetische deeltje testen
-
Eddy Current Testing Equipment
-
Penetranttesten
-
Durometer van de kust
-
brinell hardheidsmeetapparaat
-
Rockwell-hardheidsmeetapparaat
-
De micro- Hardheidsmeetapparaat van Vickers
-
Materiële hardheidstester
-
trillingsmeter
-
Test van de oppervlaktrauwheid
-
Profielprojector
-
Glancemeters
-
concrete testhamer
-
Laser-infraroodthermometer
-
BobType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
WillemType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
TomType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
LeeuwType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
HG5003 Vibration Calibrator Vibration Meter Measuring Instruments

Neem contact met me op voor gratis monsters en coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skypen: sales10@aixton.com
Als u zich zorgen maakt, bieden we 24-uurs online hulp.
xPrecisiteit | 5% | Versnellingsamplitude ((RMS)) | 90,81 m/s2 ((1 g) ± 3% |
---|---|---|---|
Uitgangsgolfvorm | Sinusgolfvorm | Golfvormvervorming | 5% |
Maximale belasting | 120Gram | Werktemperatuur | 0-55 oC |
Markeren | portable vibration meter,digital vibration meter |
HG5003 Vibration Calibratorcan be used to calibrate small vibration transducers and also vibration measuring instruments
HG5003 Vibration Calibrator
General Description
HG5003 Vibration Calibrator can be used to calibrate small vibration transducers and also vibration measuring instruments and vibration monitoring systems quickly. Standard sine signals with fixed frequency 159.2Hz and fixed amplitude is generated from the calibrator.
HG5003 Vibration Calibrator combines sine signal generator, power amplifier, standard transducer and shaker in one and features a smaller volume, high accuracy and easy operation. It can be used either in laboratory or on site.
Specifications
- Accuracy: 5%
- Acceleration Amplitude(RMS):9.81m/s2(1g)±3%
- Velocity Amplitude (RMS):9.81mm/s±3%
- Displacement Amplitude (RMS):9.81µm±3%
- Vibration Frequency:159.2Hz±0.5%
- Output waveform: Sine waveform
- Waveform distortion:£5%
- Maximum Load: 120Gram
- Battery: 9V rechargeable, Need 15 hours for fully charge
- Can make the device work for 1.5 hours
- Automatic power off time: 50seconds.
- Working temperature: 0-55 oC
- Size:Φ52×160mm
- Weight: 600 gram (with batteries)
- Tapped hole for sensor installation: M5 x 30mm
Operation
1
Fix M5 screw, accelerometer on the shaker table of the calibrator
2
Press the only switch at the calibrator to start the vibration.
3
Compare the reading of your vibration meter before the shaker power off after 50sec.
4