• HUATEC GROUP CORPORATION
    Bob
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Willem
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Tom
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Leeuw
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
Contactpersoon : Noah
Telefoonnummer : +8613911115555
WhatsApp : +8613910983110

Personal Dose Alarm Meter Radiometer X-Ray Pipeline Crawlers , Dosimeter DP802i

Plaats van herkomst Peking
Merknaam HUATEC
Certificering ISO, CE, GOST
Modelnummer DP802i
Min. bestelaantal 1 stuks
Prijs 200-300USD
Verpakking Details Standaard exportpakket
Levertijd 1-4days
Betalingscondities T/T, PayPal, Western Union
Levering vermogen 500 stuks per maand

Neem contact met me op voor gratis monsters en coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skypen: sales10@aixton.com

Als u zich zorgen maakt, bieden we 24-uurs online hulp.

x
Productdetails
Markeren

gamma ray crawler

,

pipeline crawler

Laat een bericht achter
Productomschrijving

 

Personal Dose Alarm Meter Radiometer X-Ray Pipeline Crawlers , Dosimeter DP802i

 

 

Purpose of use
Measurement of personal gamma and x-ray radiation equivalent dose rate(EDR)
Measurement of personal gamma and x-ray radiation equivalent dose (ED)
Alarm of exceeded programmed threshold levels

 

Application:

Nuclear facilities around environmental radiation detection

 

The soil surface radiation pollution detection

 

Agricultural radiation pollution detection

 

Ore, building materials radioactive detection

 

Personal dose monitoring alarm

 

Industrial X, gamma NDT radiation detection

 

Radiation medical treatment place radiation detection

 

Cobalt source, electronic accelerator irradiation place radiation detection

 

Radioactive radiation laboratory detection

 

 

Main specifications

  • Measuring range:dose rate:0.01 µSv/h ~30mSv/h
  • Cumulate dose:0.00 µSv ~999.9mSv
  • Energy range:40Kev~1.5Mev
  • Energy response error:≤±30%(according to 137Cs)
  • Relative basic error:≤±10%
  • Measuring time:automatic adjustment according to radiation, quick response
  • Alarm value:0.5, 1.0, 2.5, 10, 30, 50, 100, 500 µSv/h
  • Protective alarm response time:≤5 second
  • Display:LCD
  • Display unit:dose rate (µSv/h or mSv/h) and Cumulate dose  (µSv or mSV)—
  • Power:AAA battery 1pc, 15 days working time
  • Size:90*60*17 (mm)
  • Weight:80g