-
Ultrasone foutdetector
-
ultrasone diktemaat
-
De Maat van de deklaagdikte
-
draagbaar hardheidsmeetapparaat
-
x-ray gebrekdetector
-
Röntgenpijpleiders
-
Vakantie detector
-
het magnetische deeltje testen
-
Eddy Current Testing Equipment
-
Penetranttesten
-
Durometer van de kust
-
brinell hardheidsmeetapparaat
-
Rockwell-hardheidsmeetapparaat
-
De micro- Hardheidsmeetapparaat van Vickers
-
Materiële hardheidstester
-
trillingsmeter
-
Test van de oppervlaktrauwheid
-
Profielprojector
-
Glancemeters
-
concrete testhamer
-
Laser-infraroodthermometer
-
BobType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
WillemType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
TomType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
-
LeeuwType 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
Personal Dose Alarm Meter Radiometer X-Ray Pipeline Crawlers , Dosimeter DP802i

Neem contact met me op voor gratis monsters en coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skypen: sales10@aixton.com
Als u zich zorgen maakt, bieden we 24-uurs online hulp.
xMarkeren | gamma ray crawler,pipeline crawler |
---|
Personal Dose Alarm Meter Radiometer X-Ray Pipeline Crawlers , Dosimeter DP802i
Purpose of use
Measurement of personal gamma and x-ray radiation equivalent dose rate(EDR)
Measurement of personal gamma and x-ray radiation equivalent dose (ED)
Alarm of exceeded programmed threshold levels
Application:
Nuclear facilities around environmental radiation detection
The soil surface radiation pollution detection
Agricultural radiation pollution detection
Ore, building materials radioactive detection
Personal dose monitoring alarm
Industrial X, gamma NDT radiation detection
Radiation medical treatment place radiation detection
Cobalt source, electronic accelerator irradiation place radiation detection
Radioactive radiation laboratory detection
Main specifications
- Measuring range:dose rate:0.01 µSv/h ~30mSv/h
- Cumulate dose:0.00 µSv ~999.9mSv
- Energy range:40Kev~1.5Mev
- Energy response error:≤±30%(according to 137Cs)
- Relative basic error:≤±10%
- Measuring time:automatic adjustment according to radiation, quick response
- Alarm value:0.5, 1.0, 2.5, 10, 30, 50, 100, 500 µSv/h
- Protective alarm response time:≤5 second
- Display:LCD
- Display unit:dose rate (µSv/h or mSv/h) and Cumulate dose (µSv or mSV)—
- Power:AAA battery 1pc, 15 days working time
- Size:90*60*17 (mm)
- Weight:80g