• HUATEC GROUP CORPORATION
    Bob
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Willem
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Tom
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
  • HUATEC GROUP CORPORATION
    Leeuw
    Type 1018 het BlokKoolstofstaal Mini Iiw 2 van Astme114-15 Duim van de Kaliberbepalingstest
Contactpersoon : Noah
Telefoonnummer : +8613911115555
WhatsApp : +8613910983110

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter

Plaats van herkomst Peking
Merknaam HUATEC
Certificering ISO, CE, GOST
Modelnummer FJ-3501
Min. bestelaantal 1 stuks
Verpakking Details Standaard exportpakket
Levertijd 1-4days
Betalingscondities T/T, PayPal, Western Union
Levering vermogen 500 stuks per maand

Neem contact met me op voor gratis monsters en coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skypen: sales10@aixton.com

Als u zich zorgen maakt, bieden we 24-uurs online hulp.

x
Productdetails
Detector GGO-teller (compensatie) Meetbereik cumulatieve dosisequivalent: Hp(10)0.0μsv-9999msv
Dosisequivalent Hp ((10) 0,1 μSv/h-100 mSv/h Relatieve fout < ± 15% (137Cs) (10uSv/h-50msv/h)
Energie-respons 50 KeV-1,3 MeV, fout van 30% Hoekrespons de referentierichting 137Cs niet groter is dan ± 30% bij 0°-90°
uiterlijk grootte 50 (stijl) × 72 (lang) × 14 (dik) Gewicht 60 g
Markeren

x ray inspection equipment

,

industrial x ray machine

Laat een bericht achter
Productomschrijving

HUATEC FJ-3501 Personal Dosimeter

 

Product introduction:

FJ-3501 Personal Dosimeter is a smart pocket instrument that monitors x-rays and γ rays and can read individual doses and individual dose rates directly. Within the measuring range, the alarm threshold can be fixed or preset, and a sound and light alarm will be issued when the alarm threshold or block is blocked. The product implementation standard is "JJG 100-2006 direct reading X, γ radiation personal dose equivalent (rate) monitoring instrument”. A production license for manufacturing measuring instruments.

FJ-3501 personal dosimeter is operated by a single machine. The dose and dose rate data can be read directly by LCD. Within the measurement range, all kinds of threshold alarm values can be set arbitrarily, and sound and light alarm will be issued to remind the staff to pay attention to safety. The instrument is equipped with alarm of dose and dose rate exceeding threshold, alarm of working overtime, alarm of detector block, alarm of battery undervoltage and alarm of memory gradually full.

Personal dosimeter FJ3501 type main technical indicators meet the national standards and international standards, is the current domestic similar instruments in the strong function, small volume, low power consumption with a pocket instruments, it is widely used in nuclear military industry, nuclear power plants, industrial nondestructive flaw detection, isotope application and cobalt hospital treatment, occupational protection, residents around the plant background radiation level monitoring and other fields.

 

Technical parameters:

Detector: GM counter (compensated)

Measurement range: cumulative dose equivalent: Hp(10)0.0μsv-9999msv

Dose equivalent rate: Hp(10)0.1μSv/h-100mSv/h

Relative error: <±15% (137Cs) (10uSv/h-50msv/h)

Energy response: 50KeV-1.3MeV, error of 30%

Angle response: the reference 137Cs does not exceed the calibration direction of ±30% at 0°-90°

Alarm function: the alarm threshold can be set continuously, the alarm valve value is greater than the set alarm threshold. When the counter is blocked, continuous alarm is constant, and the alarm sound intensity is greater than 80dB at 30cm.

Power consumption: a 1.5v alkaline battery section (no. 7 battery) environment under the environment, continuous use of 72 hours, power consumption < 3mW.

Appearance size: 50 (style)×72 (long)×14 (thick)

Weight: 60g

 

Characteristic curve

 

Energy response characteristics

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 0

 

Dose-rate response characteristics:

 

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 1

 

Angular response characteristics

 

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 2Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 3

 

Performance characteristics:

Small size, light weight, with back clamp, easy to carry

The sensitivity of the instrument is high, which also has a response to the environment background. Overload blocking alarm

Use a common battery, low power consumption

Strong resistance to electromagnetic interference

 

Application field:

It is applicable to the protection and personal dose monitoring of workers in the fields of industrial nondestructive testing, isotope application, nuclear industry, hospital, railway, civil aviation, environmental protection and other radioactive applications